DXi9200 Site Planning

The DXi9200 disk backup and replication appliance uses Quantum’s data deduplication technology to expand the amount of backup data users can retain on fast-recovery RAID systems by 10 to 50 times. The result is a cost-effective way to store backup data, providing high speed, reliable restores, increasing available data recovery points, and reducing media management.
For disaster recovery in distributed environments, DXi9200 Systems make automated WAN replication practical by dramatically reducing the bandwidth required to move backup data securely between sites.
DXi9200 solutions are integrated systems that are easy to install and use with all leading backup applications. They provide best-in-class performance with flexible, easy-to-use interface options including NAS, OST, virtual library, or mixed presentations, as well as Ethernet, Fibre Channel connectivity. The DXi9200 appliance is part of a comprehensive set of backup solutions, serviced and supported by Quantum, the leading global specialist in backup, recovery, and archive.

The DXi9200 is fully configured to your specifications and pre-tested in the factory. Every DXi9200 system arrives with all necessary parts and licenses installed for the configuration as ordered. Each system comes with an accessory kit containing rack-mount hardware and installation instructions.
Note: The DXi9200 systems use DXi9200 Array Modules. The number of array modules is determined by your configuration.

The following licenses are pre-installed when ordered with the DXi9200 System:
License | Description |
---|---|
VTL |
Enables the VTL interface. All VTL licenses are factory installed. |
NAS |
Enables NAS (NFS, CIFS/SMB) and Application Shares connectivity. |
Backup Application Specific (PTT) |
Enables the backup application-specific path-to-tape capability. |
Data Deduplication |
Enables data deduplication and compression. |
Replication |
Enables replication to other DXi systems. |
Storage Capacity |
Enables the purchased storage capacity for the system.
Note: If you purchase a storage capacity upgrade, you will receive a License Certificate you can use to enable the additional capacity (see Installing the Storage Capacity License). |
OST |
Enables OpenStorage backup with Veritas OST. |
Data-at-Rest Encryption |
Enables the use of the Data-at-Rest Encryption capability to secure all data stored on the DXi9200. Data-at-Rest Encryption uses Self Encrypting Drive (SED) technology to secure all data stored on the DXi9200. This includes backup file data. When Data-at-Rest Encryption is enabled, all hard drives in the DXi are paired with the disk controllers using encryption keys. After this, accessing data on the drives requires the same encryption keys and controllers that were used to write the data. This ensures that a drive that is physically removed from the DXi cannot be read using another system or device. Non-SED systems do not have or need this license. |
Dynamic Application Environment (DAE) |
Enables the use of a virtual machine environment on the DXi9200. |
Data-in-Flight Encryption |
Enables use of AES encryption (128-bit, 256-bit, or TLS with AES 256) when sending data to another system using DXi replication or OST Accent. |
Veeam |
Enables integration of Veeam Backup and Replication with the DXi9200. See DXi-Series Configuration and Best Practices Guide for Veeam Backup & Replication on the Best Practices > DXi Best Practices Guides page. |

Quantum’s DXi Accent software accelerates backups and reduces network bandwidth requirements by distributing deduplication between the backup server and DXi appliances. With DXi Accent, backup windows are reduced and network bottlenecks are eliminated.
To use DXi Accent, you must install the Quantum OST Client Plug-in on the media server. For information about installing the OST Plug-in and using DXi Accent, see OST Plug-in Configuration.

The DXi Cloud Share feature allows DXi systems to store deduplicated backup data sets to any S3 compliant public or private cloud; providing up to 70 times more efficient use of cloud storage space.


Nearly all standard four-post EIA 19” server racks are compatible with the DXi9200 rack mount kits.
See DXi9200 Configuration for system rack space requirements.

Installation and integration of DXi9200 systems by Quantum is required. Please contact your Quantum sales representative to discuss installation services.

After hardware has been installed and initially configured, you are ready to use your DXi9200. The remote management console allows you to reconfigure your DXi9200 at any time.
Required Network Information
To utilize the remote management console of the DXi9200, you must connect it to your network.
Note the following considerations:
- DHCP (Dynamic Host Configuration Protocol) is not supported. You must provide a static IP address at the time of installation.
- The default IP Address is: 10.1.1.1
You and other administrative users can always return to the remote management console to modify all DXi9200 settings, including network settings. Refer to the DXi9200 User’s Guide for additional information on initially configuring your DXi9200.

Your DXi9200 node arrives in one of the following configurations.
Configuration | Specifications |
CPU |
|
Memory |
16 (Base) or 24 (Expanded) x 64GB DDR4
|
Note: Quantum does not support changing CPUs between models. |

During network configuration, each individual interface on the DXi9200 can be configured as a subnet with its own network settings. Each physical Ethernet port can be configured as an interface. In addition, you can also create bonded interfaces (logical ports) consisting of two or more physical ports.
You can specify the type of traffic allowed on each interface (management, replication, or data). Alternately, you can allow any traffic type on an interface. In this case, the routing of different traffic types, as well as firewall capability, must be controlled using the network infrastructure switches where the DXi9200 is connected.
Note: Each configured network interface requires its own set of network settings (IP address, network mask, and gateway).
For effective bonded network use, a properly configured network switch is required. The DXi9200 bonding settings must match the switch settings. If the switch settings and the DXi9200 settings do not match, your system may become inaccessible through the switch.
Note: A network switch is not supplied with the DXi9200.
Planning Network Configuration
Prior to installation of the DXi9200, make sure to work with your network administrator to determine the network settings that will be needed to properly integrate the DXi9200 with your network infrastructure. Consider the following questions:
- What hostname will the DXi be assigned?
- What are the default gateway and DNS servers for your company?
- How many Ethernet cables (1/10/25/100 GbE) will be connected to the DXi?
- Will you configure Ethernet ports individually or bond multiple ports into a single network device?
- If bonding Ethernet ports, what bonding mode is compatible with your network switch (Round Robin, LACP, or Active Backup)?
- How many IP addresses (network interfaces) are required, and what traffic types will be allowed on each interface (Management, Data, and Replication)?
- Will you assign a VLAN Tag ID to an interface?
- Will an interface use Jumbo Frame MTU size?
- What is the IP address, network mask, and gateway to use for each network interface?
- Will host routes be required to communicate with systems that are on subnets not reachable through the default gateway?

DXi uses the following firewall ports for its operations:
TCP Ports Opened for Management Traffic |
|
TCP Ports Opened for DXi Replication Traffic |
|
TCP Ports Opened for Data Traffic |
|
UDP Ports Opened for Data Traffic |
|


One-Year Warranty. Service Requests (SRs) can be submitted via Quantum's Online Service Request Form or telephone 24x7x365. SRs will receive a response no later than the next business day. Telephone support will include diagnosis of covered warranty issues and parts replacement. Replacement parts will be shipped within one business day of Quantum's determination that a replacement part is required. Customer will perform the replacement and return of all identified CRU (Customer Replaceable Unit) components. Identified FRU (Field Replaceable Unit) components will be replaced onsite by a Quantum Field Engineer or Authorized Service Provider, with a next business day onsite response. Onsite support for FRU replacement is provided on a Next Business Day (excluding weekends, evenings and holidays) response following determination, by Quantum, that FRU replacement is the right action to resolve the equipment or operational problem that led to the creation of the Service Request. Support includes the rights for the customer to receive new software releases applicable to registered equipment under this warranty.
Customer Replaceable Units (CRUs)
Note: Your specific CRUs are dependent on your DXi9200 system and configuration. |
|
Note: The above lists may not be comprehensive. For additional information on CRUs and FRUs, please contact your Quantum sales representative.

Quantum’s Global Service organization is geared towards delivering the fastest possible response and root cause resolution, helping you maximize your backup investments, better manage processes, and make the best use of your resources. We ensure total customer satisfaction by providing comprehensive, responsive services on a worldwide basis.
Quantum service engineers are available around the world and are deployed to respond to onsite service demands. In addition, spare part depots are strategically located across the globe; service technicians have access to the parts and equipment necessary to maintain or repair your DXi9200.
Quantum Support Options
Cloud-Based Analytics (CBA) is the latest technology for ensuring world class support for Quantum DXi products.
For an overview of CBA Capabilities, see Enable and Disable Cloud-Based Analytics. To configure CBA for your system, complete the steps in Configure Cloud Based Analytics (CBA).
Quantum offers a variety of support options to meet a range of budget and availability requirements:
StorageCare Bronze Support - (5x9 phone x NBD parts delivery
Bronze delivers support essentials during business hours, including access to skilled technical support, next-business-day delivery of replacement parts, and installation of non-customer replaceable components to ensure trouble-free problem resolution.
Note: Customer may include, at an additional charge, the commitment of Quantum to deliver onsite installation of Customer Replaceable Units (CRUs).
StorageCare NBD Gold Support - (24x7 phone x NBD parts delivery)
NBD Gold offers around-the-clock support for busy operations, quickly getting your systems back up and running. NBD Gold includes 24x7 technical assistance, proactive remote monitoring, next-business-day parts delivery, installation of non-customer replaceable components, and provisional loaner systems in times of disaster.
Note: Customer may include, at an additional charge, the commitment of Quantum to deliver onsite installation of Customer Replaceable Units (CRUs).
StorageCare Gold Support - (24x7 phone x 4 parts delivery)
Critical IT environments are always on: nights, weekends, and holidays. This support plan provides mission-critical support for fastest resolution, including 24x7 technical assistance, proactive remote monitoring and resolution, priority onsite critical issue response, 24x7 delivery and installation of all replacement parts.
Note: Gold Support includes, at no additional charge, the commitment of Quantum to deliver onsite installation of Customer Replaceable Units (CRUs).
You can initiate (CBA) from the DXi GUI using the steps in Configure Cloud Based Analytics (CBA).

Quantum recommends configuring the Email Reports capability to automatically send XML-based reports to e-mail recipients.
The report represents a snapshot of the system information at the time the report is generated. Quantum recommends generating and saving a report before performing a software upgrade or reconfiguring the system.

DXi Advanced Reporting, which is included on all DXi appliances, sets new standards for onboard intelligence by giving users a detailed view of internal appliance operations and provides them with years of backup and replication data for extended trend analysis. DXi Advanced Reporting reduces administration time, improves operations, streamlines performance tuning, and helps users maximize the value of their DXi appliances.

The Quantum DXi9200 System can be ordered in the following configurations:
Configuration |
Licensed Usable Capacity1, 2 (TB)3 | System Memory (GB) | Drives (1.92 GB NvMe) | 5U84 Array Modules (RBODs) | Total Rack Space Required |
---|---|---|---|---|---|
|
110 | 1024 | 8 |
1 |
7U |
165 | 1024 | 8 | 1 | 7U | |
220 | 1024 | 8 | 1 | 7U | |
275 | 1024 | 8 | 1 | 7U | |
330 | 1024 | 8 | 1 | 7U | |
385 | 1024 | 8 | 1 | 7U | |
440 | 1024 | 8 | 1 | 7U | |
495 | 1024 | 8 | 1 | 7U | |
550 | 1024 | 8 | 1 | 7U | |
605 | 1024 | 8 | 1 | 7U | |
660 | 1024 | 8 | 1 | 7U | |
715 | 1024 | 8 | 1 | 7U | |
770 | 1024 | 8 | 1 | 7U | |
825 | 1024 | 8 | 1 | 7U | |
880 | 1024 | 8 | 1 | 7U | |
935 | 1024 | 8 | 1 | 7U | |
990 | 1024 | 8 | 1 | 7U | |
1045 | 1024 | 8 | 1 | 7U | |
1100 | 1024 | 8 | 1 | 7U | |
1155 | 1536 | 16 | 2 | 12U | |
1210 | 1536 | 16 | 2 | 12U | |
1265 | 1536 | 16 | 2 | 12U | |
1320 | 1536 | 16 | 2 | 12U | |
1375 | 1536 | 16 | 2 | 12U | |
1430 | 1536 | 16 | 2 | 12U | |
1485 | 1536 | 16 | 2 | 12U | |
1540 | 1536 | 16 | 2 | 12U | |
1595 | 1536 | 16 | 2 | 12U | |
1650 | 1536 | 16 | 2 | 12U | |
1705 | 1536 | 16 | 2 | 12U | |
1815 | 1536 | 16 | 2 | 12U | |
1870 | 1536 | 16 | 2 | 12U | |
1925 | 1536 | 16 | 2 | 12U | |
1980 | 1536 | 16 | 2 | 12U | |
2035 | 1536 | 16 | 2 | 12U | |
2090 | 1536 | 16 | 2 | 12U | |
2145 | 1536 | 16 | 2 | 12U | |
2200 | 1536 | 16 | 2 | 12U | |

The DXi9200 is delivered in the following configurations. The Node, Array Module (RBOD), and RBOD drives ship in a separate boxes. All boxes for each DXi9200 configuration are combined on one to two shipping pallets.
Component | Shipping Information | Quantity Included Per Configuration | |
110- 1100 TB Licensed Usable Capacity |
1155 - 2200 TB Licensed Usable Capacity |
||
Node | Width:26 in. (66 cm) Length:46 in. (117 cm) Height:18 in. (45.7 cm) Weight: 110 lbs. (49.9 kg) |
1 | 1 |
Array Module (RBOD) |
Width: 24 in. (61 cm) Length: 44 in. (112 cm) Height: 17 in. (43.2 cm) Weight:274 lbs.(124 kg) |
1 | 2 |
RBOD Drive Kit (14 drives per kit). | Width: 17 in. (44 cm) Length: 20 in. (51 cm) Height: 8.5 in. (21.6 cm) Weight:27 lbs (12.2 kg) |
1-5 | 6 - 101 |
1 1-5 per Array Module |

Note: DXi9200 systems use Array Modules (RBODs). The number of array modules is determined by your configuration.
The following tables provide dimensions and other physical characteristics of the DXi9200 system components:

|
DXi Node |
Array (RBOD) Modules |
---|---|---|
Height |
2U 3.42 in. 8.68 cm |
5U 8.65 in. 22 cm |
Width (side to side) |
17.1 in. 43.4 cm |
19.0 in. 48.3 cm |
Depth (front to back) |
29.0 in. 73.7 cm |
38.6 in. 98 cm |
Weight (stand alone) |
79.6 lb 36.1 kg |
No Drives - 180 lb (81.6 kg) Drives - Up to 298 lb (135 kg) |
Rack Space Required |
2U |
5U |
Air Clearance |
Open 4 in (10.2 cm) behind unit for proper air flow |

DXi9200 |
|
---|---|
Usable Capacity |
From 110 TB to 2200 TB |
Capacity Increments |
The Array Modules RBODs) provides up to 2200 TB of usable capacity, licensable in 55 TB increments. |

Ethernet Cable Drops |
(2 x 1GbE ports) - Two 1 GbE Ethernet connections for service/management operations. (4 to 16 x 10/25 GbE ports) - (SFP28 optical or DAC copper) for NAS, Application Specific, OST, and replication connectivity. (2 to 8 x 100 GbE ports) - (SFP28 optical or DAC copper) for NAS, Application Specific, OST, and replication connectivity. Note: For Cisco 5000 Series Data Center Class switches, Quantum recommends using the approved 5 meter Twinax cable type that is shipped with the DXi9200 system. Otherwise, Quantum recommends using optical (SFP+) connectivity. Note: The 10/25/100 GbE Copper (Twinax/DAC) cable options that Quantum provides do not support all switches. Some switch vendors allow only their cables to be used to connect the switches they produce. Please note the supported switches during the purchase-configuration process, and if the Twinax cables supplied by Quantum are not compatible with your switch, please obtain the vendor’s compatible Twinax cables from your switch vendor. Be sure to have these available before the system installation takes place. |
Ethernet Cables |
Note: The following cable descriptions and images do not represent each cable speed type. 10/25 GbE Optical Cable (10/25 GbE Ethernet Card) 40/100 GbE MTO/MTP Optical Cable (100 GbE Ethernet Card)
10/25 GbE Copper (DAC) Cable (10/25 GbE Ethernet Card) 40/100 GbE Copper (DAC) Cable (100 GbE Ethernet Card)
CAT6 Cable
|
Fibre Channel Drops | 2 to 8 Fibre Channel connections for path-to-tape/VTL data transfer. |
Power Outlets | Node - 2 USA type 3-prong power outlets (Nema 5-15) or 2 C13 type 3‑prong power outlets (IEC320 C13). Expansion Module (each) - 2 USA type 3-prong power outlets (Nema 5-15) or 2 C13 type 3‑prong power outlets (IEC320 C13). |

Interfaces |
|

Power Supplies and Cords |
Node Array Module (RBOD) |
Two (2) hot-swappable redundant power supplies |
Two (2) USA type 3-prong power cords with IEC320 C13 to Nema 5-15 connectors:
|
||
Two (2) C19 to C20 type 3-prong power cords with IEC320 C19 to IEC320 C20 connectors:
|
||
Voltage |
Node |
200–240 VAC |
Array Module (RBOD) |
200 - 240 VAC |
|
Frequency |
Node |
50–60Hz |
Array Module (RBOD) |
50–60Hz | |
Maximum Operating |
Node |
5.3A @ 200V 4.4A @ 240V 1032 Watts (514 Watts at idle) |
Array Module (RBOD) |
9.1A @200V 7.6A @240V 1800 Watts (1190 Watts at idle) |
|
System |
1753 BTU/Hr (Node) 6139 BTU/Hr (RBOD) |


Temperature |
Operating |
10° to 35°C (50° to 95°F) with a maximum temperature gradient of 10C (18F) per hour. Note: 35C is the maximum temperature for the DXi9200 at 950m (3,117ft). Reduce the maximum temperature by 1C/300m (1F/547ft) above 950m (3,117 ft). |
Shipping |
–40°C to 60°C (–40°F to 140°F) with a maximum temperature gradation of 20C (36F) per hour. |
|
Storage | -10 to 50C (-14 to 122F) with a maximum temperature gradation of 15C (27F) per hour | |
Relative Humidity1 |
Operating |
20% to 80% (non-condensing) with 26C (79F) maximum dew point with a maximum gradient of 10% per hour. |
Shipping |
5% to 90% (non-condensing) with 33C (91F) maximum dew point. with a maximum gradient of 10% per hour. |
|
Storage | 10% to 90% (non-condensing) with 33C (91F) maximum dew point. with a maximum gradient of 10% per hour | |
Altitude |
Operating and Storage |
– 16m to 3048m (– 50 to 10,000 ft) |
Shipping |
-16 to 12,000m (-50 to 39,370ft) |
|
1Atmosphere must be non-condensing at all times. |

Sine Vibration |
Operating |
Random 0.26 G’s, 5–350 Hz (all operation orientations). |
Non-operating |
Random 1.88 G’s, 10-500 Hz for 15 minutes (all six sides tested). |
|
Shock Vibration |
Operating |
6 G’s for 11 ms, half-sine input, 6 shock pulses in both + and – directions operational axis |
Non-operating |
71 G’s for 2 ms, half-sine input, 6 shock pulses in both + and – directions operational axis |

Acoustic output |
Operating |
Sound Pressure Level 72 dbA maximum at any operation position |

EMC/Safety |
47 CFR part 15 Class A CNS 13438 Class A CISPR 22 Class A CISPR 24 Class A EN 55022 Class A EN 55024 EN 60590-1 EN 61000-3-2 EN 61000-3-3 IEC 60950-1 ICES-003 Class A VCCI V-3/2000 Class A AS/NZS 3548 Class A KN22 Class A KN24 UL 60590-1 |
|
Immunity Tests
Standards: EN55024: 1998 +A1: 2001 +A2:2003 KN24 |
IEC 61000-4-2 (Ed. 2.0 2008-12) - Electrostatic Discharge (ESD) IEC 61000-4-3 (Ed. 3.1 2008-04) - Radiated RF Immunity IEC 61000-4-4 (Ed. 2.0 2004-07) - Electrical Fast Transient/Burst IEC 61000-4-5 (Ed. 2.0 2005-11) - Surge Immunity IEC 61000-4-6 (Ed. 2.2 2006-05) - Conducted RF Immunity IEC 61000-4-8 (Ed. 1.1 2001-03) - Magnetic Field IEC 61000-4-11 (Ed. 2.0 2004-03) - AC Dips and Interrupts |

Quantum recommends the following to ensure a stable Storage Area Network (SAN) operation with virtual or physical tape drive appliances.
Note: The information provided below is for informational purposes only. Quantum is not responsible for issues related to applying the recommendations described below. Check with your software vendor and SAN administrator to verify these recommendations for your specific production environment.
SAN Item | Recommendations |
---|---|
Disable |
|
Drivers |
|
Fibre Channel (FC) |
|
LUNs |
|
Ports |
|
Tools |
|
Zoning |
|